GAMMA LABS, INC -- SKID TEX -- 8030-00N057275
=====================  Product Identification  =====================

Product ID:SKID TEX
MSDS Date:12/13/1993
FSC:8030
NIIN:00N057275
=== Responsible Party ===
Company Name:GAMMA LABS, INC
Address:840 ARROYO AVE
City:SAN FERNANDO
State:CA
ZIP:91340
Country:US
Info Phone Num:818-365-7500
Emergency Phone Num:818-365-7500
Preparer's Name:LOWELL NORENBERG
CAGE:IO978
=== Contractor Identification ===
Company Name:GAMMA LABS, INC
Address:840 ARROYO AVE
Box:City:SAN FERNANDO
State:CA
ZIP:91340
Country:US
Phone:818-365-7500
CAGE:IO978

=============  Composition/Information on Ingredients  =============

Ingred Name:PERLITE: COMPOSED OF INGS 2-4
CAS:93763-70-3
RTECS #:SD5254000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:SODIUM POTASSIUM ALUMINUM SILICATE
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SILICA, CRYSTALLINE - CRISTOBALITE
CAS:14464-46-1
RTECS #:VV7325000
Fraction by Wt: <0.5%
OSHA PEL:SEE TABLE Z-3
ACGIH TLV:0.05 MG/M3 RDUST

Ingred Name:SILICA, CRYSTALLINE - QUARTZ
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: <0.1%
OSHA PEL:SEE TABLE Z-3

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:NONE. CHRONIC:EXCESSIVE
    INHALATION OVER LONG PERIOD MAY CAUSE HARMFUL IRRITATION; USE MASK
    SUITABLE FOR NUISANCE DUST.
Explanation of Carcinogenicity:SILICA,
    CRYSTALLINE-CRISTOBALITE/QUARTZ:IARC MONOGRAPHS, SUPP, VOL 7, PG
    341, 1987:GROUP 2A. NTP 7TH ANNUAL (SUP DAT)
Effects of Overexposure:COUGHING.
Medical Cond Aggravated by Exposure:RESPIRATORY.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
    SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN:FLUSH W/COPIOUS
    AMOUNTS OF WATER. CALL MD . EYES:ATTEMPT TO WASH OUT WITH CLEAR 
    WATER FOR AT LEAST 15 MINUTES IF UNABLETO HAVE PARTICLE REMOVED BY
    PROFESSIONAL.

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VACUUM CLEAN OR SWEEP MATERIAL; USE NIOSH/MSHA
    APPROVED RESPIRATORS SUITABLE FOR NUISANCE DUST AND EYE PROTECTION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE GOOD HOUSEKEEPING TO AVOID DUST.
Other Precautions:USE GOOD HOUSEKEEPING TO AVOID TRANSIENT DUST.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED MASK SUITABLE FOR NUISANCE
    DUST.
Ventilation:MAINTAIN DUST LEVEL BELOW TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NONE REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:CARCINOGENS, 1994:ANTICIPATED TO BE CARCINOGEN.

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:2000F,1093C
Spec Gravity:0.1-0.4(H*2O=1)
Solubility in Water:SLIGHT
Appearance and Odor:WHITE TO OFF WHITE GRANULES, NO ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN BULK CONTAINERS ACCORDING TO LOCAL,
    STATE AND FEDERAL DUMP REQUIREMENTS. NO SPECIAL TREATMENT REQUIRED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.